Page 3 
|
Symptom:
Not working and error sign (14) or error signal (A: off, B: blink)
CHECK HI-LIMIT SWITCH (32)
This error is mostly related Hi-limit switch (32), which is high-temperature
prevention device. When hot water reaches over 180F, this safety device
is automatically tripped, and the T-K1 will be shut off completely. This
Hi-limit switch will not automatically reset, it must be manually reset.
Without Temperature Controller (TK-RE01), T-K1 hot water output temperature
is set maximum 120F hot water by factory.
Even with TK-RE01,
set at 167F maximum. There are three reasons why it high limit occurs
- A, B, and C.
- Easy to heat water
to high temperature because inlet water is supplied pre-heated. If Inlet
temperature is over 120F such as pre-heating system (solar heating)
or closed circulation system (re-circulation system, any heating system,
floor-heating system) without Pump control Thermostat (for circulation
pump), high limit will happen. Contact Technical Department to get information
for installation diagram.
- Easy to heat water
up because of small flow rate. Water flow less than 0.75 GPM (gallon/minute)
cannot be used continuously. First, clean water filter properly, Increase
your flow rate manually, and change your habit to mixing water. Some
faucets will cause flow restriction of its mechanical reason.
- Computer control
trouble. It is required to check and maintain by TAKAGI Technician.
(very rare possibility)
|
|