FLASH T-K1
T-K1 Application
T-K1 Efficiency
T-K1 Optional Parts
T-K1 Service
T-K1 Specifications
T-K1 Warranty
T-K1 FAQ's
Flash T-K2
T-K2 Efficiency
T-K2 Specifications
T-K2 Warranty

MOBIUS T-M1
T-M1 Application
T-M1 Efficiency
T-M1 Optional Parts
T-M1 Specifications
T-M1 Warranty
T-M1 FAQ's
 

Gas Type

 
Natural Gas Propane or Liquid Propane

Input BTU rate

NG
Min.25,000 - Max. 235,000
LP
Min. 25,000 - Max. 225,000

Thermal Efficiency

NG
Max. 82.3%
LP
Max. 84.7%

Energy Factor

NG
0.81
LP
0.84

First Hour Rating (DOE)

 
300 GPH

Dimensions

 
24" (H) 18" (W) 9" (D)

Net Weight

 
70lbs

Water Connection

 
3/4" NPT

Gas Connection

 
3/4" NPT

Water Pressure

  
Min.15 PSI - Max. 150 PSI

Gas Pressure

NG
Min.5.0" wc- Max. 10.5" wc
LP
Min. 11" - Max. 14" wc

Electrical Supply

  
120 V, 0.8A

Water Flow Rate

  
Min. 0.75 GPM, Max. 9.6 GPM

Vent

 
4" Round Power Vent

Installation

 
Indoor or Outdoor
 
   